{"id":3355,"date":"2025-05-22T10:11:03","date_gmt":"2025-05-22T08:11:03","guid":{"rendered":"https:\/\/ergo-elektronik.de\/?page_id=3355"},"modified":"2025-05-22T10:11:03","modified_gmt":"2025-05-22T08:11:03","slug":"twt-testsysteme","status":"publish","type":"page","link":"https:\/\/ergo-elektronik.de\/en\/twt-testsysteme\/","title":{"rendered":"TWT Test Systems"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-78fbda14 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-cc414d5d\"><h2 class=\"uagb-heading-text\">TWT-Test Systems &amp;<br>High-voltage laboratory power supplies<\/h2><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-5aaee1ea alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-99129b43\">\n<div class=\"wp-block-uagb-container uagb-block-f03f8c14\">\n<div class=\"wp-block-uagb-info-box uagb-block-9df54936 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><div class=\"uagb-ifb-separator\"><\/div><h3 class=\"uagb-ifb-title\">Custom Development<\/h3><\/div><p class=\"uagb-ifb-desc\">We develop and manufacture <strong>Custom high voltage laboratory power supplies<\/strong> and <strong>Test systems <\/strong>for the manufacturing of <strong>traveling wave tubes <\/strong>(TWTs). These are used in the GHz range for amplifying weak microwave signals. They are primarily built into power output stages of data transmission, which are needed in satellite communication and in civilian\/military radar devices, for example in airports, aircraft, missiles, and ships.&nbsp;<\/p><\/div><\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-78f2b250\"><div class=\"uagb-separator-spacing-wrapper\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-e5074e87 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-20d8743c\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-c8f219c9\"><h2 class=\"uagb-heading-text\"><strong>Laboratory TWT Power Supply<\/strong><\/h2><div class=\"uagb-separator\"><\/div><\/div>\n\n\n\n<p class=\"has-ast-global-color-3-color has-text-color has-link-color wp-elements-a46a43e12f3ebfacd0c38ac4094be68b\"><strong>Description<\/strong><br>Helix \/ Cathode Supply 11kV \/ 330W<br>4 Collector Supplies 1.2 kW each<br>Grid Modulator 500V swing, PRF 650kHz<br>Ion Pump and Heater Power Supplies<br>Internal IPC-Control with IEC-Bus Interface<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-image alignright uagb-block-9c77f9ac wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-right\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/HVPS-11kV-878x1024.jpg ,https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/HVPS-11kV.jpg 780w, https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/HVPS-11kV.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/HVPS-11kV-878x1024.jpg\" alt=\"\" class=\"uag-image-3399\" width=\"500\" height=\"600\" title=\"11kV HVPS\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-6cad977d\"><div class=\"uagb-separator-spacing-wrapper\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-edbda12b alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-5f7fc0b9\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-cc939b38\"><h2 class=\"uagb-heading-text\"><strong>Laboratory TWT Power Supply<\/strong><\/h2><div class=\"uagb-separator\"><\/div><\/div>\n\n\n\n<p class=\"has-ast-global-color-3-color has-text-color has-link-color wp-elements-9286ceaf8abe303830fbebc9b5009524\"><strong>Description<\/strong><br>Helix\/Cathode Supply 35kV\/4kW<br>4 collectors, 4kW to 8kW each<br>Grid Modulator 3.5kV swing, PRF 30kHz<br>Anode, Ion Pump, and Heater Power Supplies<br>Scope on HV Potential<br>IEC-Bus Interface<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-image alignright uagb-block-e44c7c41 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-right\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/Front-view-918x1024.jpg ,https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/Front-view.jpg 780w, https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/Front-view-918x1024.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/Front-view-918x1024.jpg\" alt=\"\" class=\"uag-image-3398\" width=\"500\" height=\"600\" title=\"Front view\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-bd440bfc\"><div class=\"uagb-separator-spacing-wrapper\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6a38ab55 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-0ede0a6e\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-e468be8e\"><h2 class=\"uagb-heading-text\"><strong>\u200b<strong>TWT-Power Supply with Connection Panel and PC Operator Interface<\/strong><\/strong><\/h2><div class=\"uagb-separator\"><\/div><\/div>\n\n\n\n<p class=\"has-ast-global-color-3-color has-text-color has-link-color wp-elements-440db7067c51531c5734ea472524b4fa\"><strong>Description<\/strong><br>Helix \/ Cathode Supply 10kV \/ 100W<br>5 collectors, 500W each<br>Heater, Wehnelt, IB, and Anode Supplies<br>Anode-Modulator<br>Internal IPC-Control with IEC-Bus Interface<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-image alignright uagb-block-b020e8ec wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-right\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130122_060_ERGO-Ulm__S2C1002-959x1024.jpg ,https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130122_060_ERGO-Ulm__S2C1002-scaled.jpg 780w, https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130122_060_ERGO-Ulm__S2C1002-scaled.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130122_060_ERGO-Ulm__S2C1002-959x1024.jpg\" alt=\"\" class=\"uag-image-3395\" width=\"500\" height=\"600\" title=\"20130122_060_ERGO Ulm__S2C1002\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-d3b0c08c\"><div class=\"uagb-separator-spacing-wrapper\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-47f2e0c1 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-91332762\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-a4847076\"><h2 class=\"uagb-heading-text\"><strong>Measurement and Control Module (MCM)<\/strong><\/h2><div class=\"uagb-separator\"><\/div><\/div>\n\n\n\n<p class=\"has-ast-global-color-3-color has-text-color has-link-color wp-elements-a314edab12622149160b518b78938d81\"><strong>Description<\/strong><br>The module is used for potential-free control and measurement of up to 32 networked voltage sources in TWT power supplies.&nbsp;<br>16-bit resolution.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-image alignright uagb-block-80d63580 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-right\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130926_016_ERGO-\u00a9DUCKEK-Intermetrics__S2C4496-1024x570.jpg ,https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130926_016_ERGO-\u00a9DUCKEK-Intermetrics__S2C4496-scaled.jpg 780w, https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130926_016_ERGO-\u00a9DUCKEK-Intermetrics__S2C4496-1024x570.jpg 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/ergo-elektronik.de\/wp-content\/uploads\/2025\/03\/20130926_016_ERGO-\u00a9DUCKEK-Intermetrics__S2C4496-1024x570.jpg\" alt=\"\" class=\"uag-image-3404\" width=\"650\" height=\"400\" title=\"20130926_016_ERGO \u00a9DUCKEK Intermetrics__S2C4496\" loading=\"lazy\" role=\"img\"\/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-83be65d7 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-815263f7 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-call-to-action uagb-block-fa4aa9f2 wp-block-button\"><div class=\"uagb-cta__wrap\"><h3 class=\"uagb-cta__title\">Do you want to learn more?<\/h3><p class=\"uagb-cta__desc\">Then we look forward to your <strong>Contact us!<\/strong><\/p><\/div><div class=\"uagb-cta__buttons\"><a href=\"mailto:info@ergo-elektronik.de\" class=\"uagb-cta__button-link-wrapper wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\">Send email<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M464 64C490.5 64 512 85.49 512 112C512 127.1 504.9 141.3 492.8 150.4L275.2 313.6C263.8 322.1 248.2 322.1 236.8 313.6L19.2 150.4C7.113 141.3 0 127.1 0 112C0 85.49 21.49 64 48 64H464zM217.6 339.2C240.4 356.3 271.6 356.3 294.4 339.2L512 176V384C512 419.3 483.3 448 448 448H64C28.65 448 0 419.3 0 384V176L217.6 339.2z\"><\/path><\/svg><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>TWT-Testsysteme &amp;Hochspannungs-Labornetzger\u00e4te Laboratory TWT-Power Supply Beschreibung:Helix \/ Cathode Supply 11kV \/ 330W4 Collector Supplies 1.2 kW eachGrid Modulator 500V swing, PRF 650kHzIon-Pump- and Heater Power SuppliesInternal IPC-Control with IEC-Bus Interface Laboratory TWT-Power Supply Beschreibung:Helix \/ Cathode Supply 35kV \/ 4kW4 Collector Supplies&nbsp; 4kW to 8kW eachGrid Modulator 3.5kV swing, PRF 30kHzAnode-, Ion-Pump- and Heater Power [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"full-width-container","site-content-style":"boxed","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-3355","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/ergo-elektronik.de\/en\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"TWT-Testsysteme &amp;Hochspannungs-Labornetzger\u00e4te Laboratory TWT-Power Supply Beschreibung:Helix \/ Cathode Supply 11kV \/ 330W4 Collector Supplies 1.2 kW eachGrid Modulator 500V swing, PRF 650kHzIon-Pump- and Heater Power SuppliesInternal IPC-Control with IEC-Bus Interface Laboratory TWT-Power Supply Beschreibung:Helix \/ Cathode Supply 35kV \/ 4kW4 Collector Supplies&nbsp; 4kW to 8kW eachGrid Modulator 3.5kV swing, PRF 30kHzAnode-, Ion-Pump- and Heater Power&hellip;","_links":{"self":[{"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/pages\/3355","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/comments?post=3355"}],"version-history":[{"count":15,"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/pages\/3355\/revisions"}],"predecessor-version":[{"id":3635,"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/pages\/3355\/revisions\/3635"}],"wp:attachment":[{"href":"https:\/\/ergo-elektronik.de\/en\/wp-json\/wp\/v2\/media?parent=3355"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}